This section specifies the template PhysicalElement.
The specification comprises a SysML Block that represents the template and an
associated Parametric Diagram that defines the templates and
PLCS PSMTemplate objects
instantiated by the PhysicalElement template.
The specification comprises the following sections:
- Section Description provides a
description of the template;
- Section Template Block specifies the SysML
Block that represents the template;
- Section Template Properties specifies
the properties, i.e. the SysML Part, Reference and Value properties of the
templates SysML Block;
- Section Template Output Ports
specifies the SysML Output Ports of the templates SysML Block. These bind to the
templates and PLCS PSM objects
instantiated by the PhysicalElement template as
described in section Template
Parametric Diagram;
- Section Template Constraints specifies
the constraints on PLCS PSMTemplate objects instantiated by the
PhysicalElement template;
- Section Template Parametric
Diagram specifies the templates and PLCS PSMTemplate objects instantiated by the
PhysicalElement template;
- Section Instantiated blocks specifies
the templates and PLCS PSMTemplate objects instantiated by the
PhysicalElement template and bound to private
parts of the template;
- Section Default instances species the
instances that have been instantiated in the template. These are used to set
the default value of blocks.
- Section Constraint blocks identifies the
constraint blocks that have been specified in this template;
- Section Example data
provides example XML data sets that have been instantiated in accordance
with this template.
NOTE
An explanation of a template and its specification is provided in
the
Template
overview
Represents a position (or a "hole") in the physical structure. The position (structural
element) may have an "applicability", i.e. a list of valid ItemOfSupplies that can
be used at this position.
No templates have been explicitly defined as being related to the PhysicalElement template.
NOTE
The PhysicalElement template may make reference
to other templates as part of the Parametric Diagram. These are not listed
here.
Figure 1 shows the SysML Block that represents the template. The Block is an abstraction
representing a pattern of templates and PLCS PSMTemplate objects.
The properties, i.e. the SysML Block Part, Reference and Value properties, of the
template's SysML Block are described in the Template
Properties section.
The output ports shown on the template's SysML Block are described in the template output ports section.
The SysML Parametric diagrams for the template Block are shown in template parametric diagram section.
Figure 1 - Template block definition diagram for PhysicalElement
The following SysML Part, Reference, and Value properties are defined for this template:
References:
breakdown [1..*] (Template: SwedishDefence:
PhysicalBreakdown)
Relationship to the physical structure that contains the physical structure element.
document [0..*] (Template: SwedishDefence:
Document)
Relationship to documents that are related to the physical element.
Parts:
physicalElementId [1] (Template: OASIS:
Identification)
Identifies the physical element uniquely (within a physical structure).
The reference data used in Template: OASIS:
Identification is restricted as follows:
RDL constraint 1:physicalElementId constraint
The reference data for:
OASIS:Identification.role -> ExternalOwlClass.class
is restricted to the following class or a subclass:
LCNcode [0..1] (Template: OASIS:
Descriptor)
Logistics Support Analysis (LSA) Control Number. The LCN may represent either a functional
or hardware generation breakdown/disassembly sequence of system/equipment hardware
including support equipment, training equipment, and installation (connecting) hardware.
Alternative identification of the physical element, unique within the physical structure.
The reference data used in Template: OASIS:
Descriptor is restricted as follows:
RDL constraint 1:LCNcode constraint
The reference data for:
OASIS:Descriptor.classifiedAs -> ExternalOwlClass.class
is restricted to the following class or a subclass:
mandatoryPhysicalElement [0..1] (Template: OASIS:
Classifier)
Classification of the physical element as being mandatory in the structure, i.e. it
has to be realized in order to use the product.
The reference data used in Template: OASIS:
Classifier is restricted as follows:
RDL constraint 1:mandatoryPhysicalElement constraint
The reference data for:
OASIS:Descriptor.classifiedAs -> ExternalOwlClass.class
is restricted to the following class or a subclass:
mountingRule [0..1] (ValueType:
ExternalOwlClass)
Physical structure element that is classified according mounting rules.
The reference data used is restricted to the following set:
The reference data used in is restricted as follows:
RDL constraint 1:MountingRule constraint
The reference data for:
OASIS:Classifier.class -> ExternalOwlClass.class
is restricted to the following class or a subclass:
physicalElementVersionId [0..1] (Template: OASIS:
Identification)
Identifies a physical meter element version uniquely (within the physical element)
The reference data used in Template: OASIS:
Identification is restricted as follows:
RDL constraint 1:physicalElementName constraint
The reference data for:
OASIS:Identification.role -> ExternalOwlClass.class
is restricted to the following class or a subclass:
physicalElementName [0..1] (Template: OASIS:
Name)
Name of the physical meter element.
The reference data used in Template: OASIS:
Name is restricted as follows:
RDL constraint 1:physicalElementName constraint
The reference data for:
OASIS:Descriptor.classifiedAs -> ExternalOwlClass.class
is restricted to the following class or a subclass:
lineReplaceableUnit [0..1] (Template: OASIS:
Classifier)
A modular component designed to be replaced quickly typically to undergo repair and
overhaul actions in other support locations.
The reference data used in Template: OASIS:
Classifier is restricted as follows:
RDL constraint 1:lineReplaceableUnit constraint
The reference data for:
OASIS:Classifier.class -> ExternalOwlClass.class
is restricted to the following class or a subclass:
The following output ports are defined for this template:
There are no constraints defined for this template.
This section describes the template's Parametric Diagram. The diagram details
the pattern of templates and PLCS PSMTemplate objects that are required to
represent the template PhysicalElement.
The public properties, i.e. those visible in the template's SysML block (See Figure 1) are shown on the left of a
Parametric Diagram.
NOTE
Restrictions on the reference data to be set on the public properties is
defined in the
Template Properties section.
The output ports are shown on the right of a Parametric Diagram.
PLCS PSM
objects are shaded khaki and
Templates
are shaded light green in a Parametric Diagram.
Figure 2 - PhysicalElement
The following blocks are instantiated by this template and bound to private parts
of the
template as shown in the Parametric Diagram
section:
Protected Part Property:
PhysicalStructureElement [1] (Template: OASIS:
PhysicalElement)
Private Reference Property:
classPhysicalStructureElement [1] (Block: Ap239Ap233Psm:
ExternalOwlClass)
The following constraint, normally a uniqueness constraint, is
applicable when instantiating the ExternalOwlClass:
rule.Ap239Ap233Psm.ExternalOwlClass.ur1
Constraint: ur1Specification: (OCL2.0)
ExternalOwlClass::allInstances()->isUnique(class)
Private Part Property:
PhysicalStructureElementClass [1] (Template: OASIS:
Classifier)
Protected Part Property:
combineClassifiers [1] (Constraint Block: OASIS:Classifier:
CombineClassifiers)
Private Part Property:
mountingClass [0..1] (Template: OASIS:
Classifier)
Private Part Property:
breakdownContext [1..*] (Block: Ap239Ap233Psm:
BreakdownContext)
The following constraint, normally a uniqueness constraint, is
applicable when instantiating the BreakdownContext:
rule.Ap239Ap233Psm.ExternalOwlClass.ur1
Constraint: ur1Specification: (OCL2.0)
BreakdownContext::allInstances()->isUnique(Sequence{breakdown, breakdownElement})
Private Part Property:
pda [0..*] (Block: Ap239Ap233Psm:
PropertyDefinitionAssignment)
The following constraint, normally a uniqueness constraint, is
applicable when instantiating the PropertyDefinitionAssignment:
rule.Ap239Ap233Psm.ExternalOwlClass.ur1
Constraint: UR1Specification: (OCL2.0)
PropertyDefinitionAssignment::allInstances()->isUnique(Sequence{assignedTo, assignedPropertyDefinition})
There are no instances that have been instantiated in this template.
There are no constraint blocks defined in this template.
No example data sets have been provided for this Template.