Template: SwedishDefence:PhysicalElement

This section specifies the template PhysicalElement.

The specification comprises a SysML Block that represents the template and an associated Parametric Diagram that defines the templates and PLCS PSMTemplate objects instantiated by the PhysicalElement template.

The specification comprises the following sections:

NOTE    An explanation of a template and its specification is provided in the Template overview
Represents a position (or a "hole") in the physical structure. The position (structural element) may have an "applicability", i.e. a list of valid ItemOfSupplies that can be used at this position.

No templates have been explicitly defined as being related to the PhysicalElement template.

NOTE    The PhysicalElement template may make reference to other templates as part of the Parametric Diagram. These are not listed here.

Figure 1 shows the SysML Block that represents the template. The Block is an abstraction representing a pattern of templates and PLCS PSMTemplate objects.

The properties, i.e. the SysML Block Part, Reference and Value properties, of the template's SysML Block are described in the Template Properties section.

The output ports shown on the template's SysML Block are described in the template output ports section.

The SysML Parametric diagrams for the template Block are shown in template parametric diagram section.

Figure 1 -  Template block definition diagram for PhysicalElement

The following SysML Part, Reference, and Value properties are defined for this template:

References:
breakdown [1..*] (Template: SwedishDefence:PhysicalBreakdown)
Relationship to the physical structure that contains the physical structure element.
document [0..*] (Template: SwedishDefence:Document)
Relationship to documents that are related to the physical element.
hasProperties [0..*] (Template: SwedishDefence:OperationalPropertyDefinition)
The operational properties to be followed-up for the position.
interfaceConnector [0..*] (Template: SwedishDefence:InterfaceConnector)
Relationship to interface connectors that a physical element consists of.
Parts:
physicalElementId [1] (Template: OASIS:Identification)
Identifies the physical element uniquely (within a physical structure).
The reference data used in Template: OASIS:Identification is restricted as follows:
RDL constraint 1:
physicalElementId constraint
The reference data for:
OASIS:Identification.role -> ExternalOwlClass.class
is restricted to the following class or a subclass:
LCNcode [0..1] (Template: OASIS:Descriptor)
Logistics Support Analysis (LSA) Control Number. The LCN may represent either a functional or hardware generation breakdown/disassembly sequence of system/equipment hardware including support equipment, training equipment, and installation (connecting) hardware. Alternative identification of the physical element, unique within the physical structure.
The reference data used in Template: OASIS:Descriptor is restricted as follows:
RDL constraint 1:
LCNcode constraint
The reference data for:
OASIS:Descriptor.classifiedAs -> ExternalOwlClass.class
is restricted to the following class or a subclass:
mandatoryPhysicalElement [0..1] (Template: OASIS:Classifier)
Classification of the physical element as being mandatory in the structure, i.e. it has to be realized in order to use the product.
The reference data used in Template: OASIS:Classifier is restricted as follows:
RDL constraint 1:
mandatoryPhysicalElement constraint
The reference data for:
OASIS:Descriptor.classifiedAs -> ExternalOwlClass.class
is restricted to the following class or a subclass:
mountingRule [0..1] (ValueType: ExternalOwlClass)
Physical structure element that is classified according mounting rules.
The reference data used in is restricted as follows:
RDL constraint 1:
MountingRule constraint
The reference data for:
OASIS:Classifier.class -> ExternalOwlClass.class
is restricted to the following class or a subclass:
physicalElementVersionId [0..1] (Template: OASIS:Identification)
Identifies a physical meter element version uniquely (within the physical element)
The reference data used in Template: OASIS:Identification is restricted as follows:
RDL constraint 1:
physicalElementName constraint
The reference data for:
OASIS:Identification.role -> ExternalOwlClass.class
is restricted to the following class or a subclass:
physicalElementName [0..1] (Template: OASIS:Name)
Name of the physical meter element.
The reference data used in Template: OASIS:Name is restricted as follows:
RDL constraint 1:
physicalElementName constraint
The reference data for:
OASIS:Descriptor.classifiedAs -> ExternalOwlClass.class
is restricted to the following class or a subclass:
lineReplaceableUnit [0..1] (Template: OASIS:Classifier)
A modular component designed to be replaced quickly typically to undergo repair and overhaul actions in other support locations.
The reference data used in Template: OASIS:Classifier is restricted as follows:
RDL constraint 1:
lineReplaceableUnit constraint
The reference data for:
OASIS:Classifier.class -> ExternalOwlClass.class
is restricted to the following class or a subclass:

The following output ports are defined for this template:

PSMphysicaElelementDefinition (Block: Ap239Ap233Psm:PhysicalElementDefinition)
Enables the Block: Ap239Ap233Psm:PhysicalElementDefinition instantiated by this template to be referenced when the template is used.
PSMphysicalBreakdownContext (Block: Ap239Ap233Psm:PhysicalBreakdownContext)
Enables the Block: Ap239Ap233Psm:PhysicalBreakdownContext instantiated by this template to be referenced when the template is used.
PSMphysicalElementVersion (Block: Ap239Ap233Psm:PhysicalElementVersion)
Enables the Block: Ap239Ap233Psm:PhysicalElementVersion instantiated by this template to be referenced when the template is used.
PSMphysicalElement (Block: Ap239Ap233Psm:PhysicalElement)
Enables the Block: Ap239Ap233Psm:PhysicalElement instantiated by this template to be referenced when the template is used.
OASISphysicalElement (Template: OASIS:PhysicalElement)
Enables the Template: OASIS:PhysicalElement instantiated by this template to be referenced when the template is used.

There are no constraints defined for this template.

This section describes the template's Parametric Diagram. The diagram details the pattern of templates and PLCS PSMTemplate objects that are required to represent the template PhysicalElement.

The public properties, i.e. those visible in the template's SysML block (See Figure 1) are shown on the left of a Parametric Diagram.

NOTE    Restrictions on the reference data to be set on the public properties is defined in the Template Properties section.

The output ports are shown on the right of a Parametric Diagram.

PLCS PSM objects are shaded khaki and Templates are shaded light green in a Parametric Diagram.

Figure 2 -  PhysicalElement

The following blocks are instantiated by this template and bound to private parts of the template as shown in the Parametric Diagram section:

Protected Part Property:PhysicalStructureElement [1] (Template: OASIS:PhysicalElement)
Private Reference Property:classPhysicalStructureElement [1] (Block: Ap239Ap233Psm:ExternalOwlClass)

The following constraint, normally a uniqueness constraint, is applicable when instantiating the ExternalOwlClass:

rule.Ap239Ap233Psm.ExternalOwlClass.ur1
Constraint: ur1
Specification: (OCL2.0)
ExternalOwlClass::allInstances()->isUnique(class)
Private Part Property:PhysicalStructureElementClass [1] (Template: OASIS:Classifier)
Private Reference Property:pseVdc [1] (Template: OASIS:ViewDefinitionContext)
Protected Part Property:combineClassifiers [1] (Constraint Block: OASIS:Classifier:CombineClassifiers)
Private Part Property:mountingClass [0..1] (Template: OASIS:Classifier)
Private Part Property:breakdownContext [1..*] (Block: Ap239Ap233Psm:BreakdownContext)

The following constraint, normally a uniqueness constraint, is applicable when instantiating the BreakdownContext:

rule.Ap239Ap233Psm.ExternalOwlClass.ur1
Constraint: ur1
Specification: (OCL2.0)
BreakdownContext::allInstances()->isUnique(Sequence{breakdown, breakdownElement})
Private Part Property:documentAsg [0..*] (Block: Ap239Ap233Psm:DocumentAssignment)
Private Part Property:beric [0..*] (Template: OASIS:BreakdownElementRealization)
Private Part Property:pda [0..*] (Block: Ap239Ap233Psm:PropertyDefinitionAssignment)

The following constraint, normally a uniqueness constraint, is applicable when instantiating the PropertyDefinitionAssignment:

rule.Ap239Ap233Psm.ExternalOwlClass.ur1
Constraint: UR1
Specification: (OCL2.0)
PropertyDefinitionAssignment::allInstances()->isUnique(Sequence{assignedTo, assignedPropertyDefinition})

There are no instances that have been instantiated in this template.

There are no constraint blocks defined in this template.

No example data sets have been provided for this Template.

Issue reporting