Template:- SwedishDefence:MeterReading
The MeterReading template describes how to represent a measurement record of a specific operational property of a MeterIndividual.
Template Properties

The following SysML Part, Reference, and Value properties are defined for this template:

References:
individualMeterRead [1] (Template: SwedishDefence:MeterIndividual)
The individual meter used.
meterReadingFaultCode [0..*] (Template: SwedishDefence:FaultCode)
Specific fault code that the meter may display.
protocolValue [0..1] (Template: SwedishDefence:BinaryValueFile)
Relationship to a binary value file that presents the protocol value of the meter reading.
Parts:
meterReadingIdentifier [1] (Template: OASIS:Identification)
Identifier of the meter reading.
meterReadingValue [0..*] (Template: SwedishDefence:MeasuredValue)
Specific value that the meter is displayed.
Values:
readingTime [1] (Block: Ap239Ap233Psm:DateTimeString)
Time of reading of the meter individual.

The following constraint, normally a uniqueness constraint, is applicable when instantiating the DateTimeString:

rule.Ap239Ap233Psm.ExternalOwlClass.ur1
Constraint: XSDDATETIME
Specification: (OCL2.0)
self.matches('[0-9]{4}-[0-9]{2}-[0-9]{2}T[0-9]{2}:[0-9]{2}:[0-9]{2}Z')
sequenceNumber [0..1] (Real)
Number indicates the sequence of the meter reading.