Template:- SwedishDefence:PhysicalElement
Represents a position (or a "hole") in the physical structure. The position (structural element) may have an "applicability", i.e. a list of valid ItemOfSupplies that can be used at this position.
Template Properties

The following SysML Part, Reference, and Value properties are defined for this template:

References:
breakdown [1..*] (Template: SwedishDefence:PhysicalBreakdown)
Relationship to the physical structure that contains the physical structure element.
document [0..*] (Template: SwedishDefence:Document)
Relationship to documents that are related to the physical element.
hasProperties [0..*] (Template: SwedishDefence:OperationalPropertyDefinition)
The operational properties to be followed-up for the position.
interfaceConnector [0..*] (Template: SwedishDefence:InterfaceConnector)
Relationship to interface connectors that a physical element consists of.
Parts:
physicalElementId [1] (Template: OASIS:Identification)
Identifies the physical element uniquely (within a physical structure).
The reference data used in Template: OASIS:Identification is restricted as follows:
RDL constraint 1:
physicalElementId constraint
The reference data for:
OASIS:Identification.role -> ExternalOwlClass.class
is restricted to the following class or a subclass:
LCNcode [0..1] (Template: OASIS:Descriptor)
Logistics Support Analysis (LSA) Control Number. The LCN may represent either a functional or hardware generation breakdown/disassembly sequence of system/equipment hardware including support equipment, training equipment, and installation (connecting) hardware. Alternative identification of the physical element, unique within the physical structure.
The reference data used in Template: OASIS:Descriptor is restricted as follows:
RDL constraint 1:
LCNcode constraint
The reference data for:
OASIS:Descriptor.classifiedAs -> ExternalOwlClass.class
is restricted to the following class or a subclass:
mandatoryPhysicalElement [0..1] (Template: OASIS:Classifier)
Classification of the physical element as being mandatory in the structure, i.e. it has to be realized in order to use the product.
The reference data used in Template: OASIS:Classifier is restricted as follows:
RDL constraint 1:
mandatoryPhysicalElement constraint
The reference data for:
OASIS:Descriptor.classifiedAs -> ExternalOwlClass.class
is restricted to the following class or a subclass:
mountingRule [0..1] (ValueType: ExternalOwlClass)
Physical structure element that is classified according mounting rules.
The reference data used in is restricted as follows:
RDL constraint 1:
MountingRule constraint
The reference data for:
OASIS:Classifier.class -> ExternalOwlClass.class
is restricted to the following class or a subclass:
physicalElementVersionId [0..1] (Template: OASIS:Identification)
Identifies a physical meter element version uniquely (within the physical element)
The reference data used in Template: OASIS:Identification is restricted as follows:
RDL constraint 1:
physicalElementName constraint
The reference data for:
OASIS:Identification.role -> ExternalOwlClass.class
is restricted to the following class or a subclass:
physicalElementName [0..1] (Template: OASIS:Name)
Name of the physical meter element.
The reference data used in Template: OASIS:Name is restricted as follows:
RDL constraint 1:
physicalElementName constraint
The reference data for:
OASIS:Descriptor.classifiedAs -> ExternalOwlClass.class
is restricted to the following class or a subclass:
lineReplaceableUnit [0..1] (Template: OASIS:Classifier)
A modular component designed to be replaced quickly typically to undergo repair and overhaul actions in other support locations.
The reference data used in Template: OASIS:Classifier is restricted as follows:
RDL constraint 1:
lineReplaceableUnit constraint
The reference data for:
OASIS:Classifier.class -> ExternalOwlClass.class
is restricted to the following class or a subclass: