Represents a position (or a "hole") in the physical structure. The position (structural
element) may have an "applicability", i.e. a list of valid ItemOfSupplies that can
be used at this position.
The following SysML Part, Reference, and Value properties are defined for this template:
References:
breakdown [1..*] (Template: SwedishDefence:
PhysicalBreakdown)
Relationship to the physical structure that contains the physical structure element.
document [0..*] (Template: SwedishDefence:
Document)
Relationship to documents that are related to the physical element.
Parts:
physicalElementId [1] (Template: OASIS:
Identification)
Identifies the physical element uniquely (within a physical structure).
The reference data used in Template: OASIS:
Identification is restricted as follows:
RDL constraint 1:physicalElementId constraint
The reference data for:
OASIS:Identification.role -> ExternalOwlClass.class
is restricted to the following class or a subclass:
LCNcode [0..1] (Template: OASIS:
Descriptor)
Logistics Support Analysis (LSA) Control Number. The LCN may represent either a functional
or hardware generation breakdown/disassembly sequence of system/equipment hardware
including support equipment, training equipment, and installation (connecting) hardware.
Alternative identification of the physical element, unique within the physical structure.
The reference data used in Template: OASIS:
Descriptor is restricted as follows:
RDL constraint 1:LCNcode constraint
The reference data for:
OASIS:Descriptor.classifiedAs -> ExternalOwlClass.class
is restricted to the following class or a subclass:
mandatoryPhysicalElement [0..1] (Template: OASIS:
Classifier)
Classification of the physical element as being mandatory in the structure, i.e. it
has to be realized in order to use the product.
The reference data used in Template: OASIS:
Classifier is restricted as follows:
RDL constraint 1:mandatoryPhysicalElement constraint
The reference data for:
OASIS:Descriptor.classifiedAs -> ExternalOwlClass.class
is restricted to the following class or a subclass:
mountingRule [0..1] (ValueType:
ExternalOwlClass)
Physical structure element that is classified according mounting rules.
The reference data used is restricted to the following set:
The reference data used in is restricted as follows:
RDL constraint 1:MountingRule constraint
The reference data for:
OASIS:Classifier.class -> ExternalOwlClass.class
is restricted to the following class or a subclass:
physicalElementVersionId [0..1] (Template: OASIS:
Identification)
Identifies a physical meter element version uniquely (within the physical element)
The reference data used in Template: OASIS:
Identification is restricted as follows:
RDL constraint 1:physicalElementName constraint
The reference data for:
OASIS:Identification.role -> ExternalOwlClass.class
is restricted to the following class or a subclass:
physicalElementName [0..1] (Template: OASIS:
Name)
Name of the physical meter element.
The reference data used in Template: OASIS:
Name is restricted as follows:
RDL constraint 1:physicalElementName constraint
The reference data for:
OASIS:Descriptor.classifiedAs -> ExternalOwlClass.class
is restricted to the following class or a subclass:
lineReplaceableUnit [0..1] (Template: OASIS:
Classifier)
A modular component designed to be replaced quickly typically to undergo repair and
overhaul actions in other support locations.
The reference data used in Template: OASIS:
Classifier is restricted as follows:
RDL constraint 1:lineReplaceableUnit constraint
The reference data for:
OASIS:Classifier.class -> ExternalOwlClass.class
is restricted to the following class or a subclass: